Special Summer Sale Limited Time 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: 70percent

International Code Council Fire-Inspector-II 67 - Fire Inspector II Exam Exam Practice Test

67 - Fire Inspector II Exam Questions and Answers

Question 1

A permit is required for storage of high-pile combustible stock in a building when the area of stock exceeds

Options:

A.

225

B.

500

C.

1,000

D.

2,500

Question 2

Platforms used for access to aboveground tanks storing flammable or combustible liquids shall be:

Options:

A.

at least 4 ft. wide.

B.

built of noncombustible construction.

C.

built of nonferrous, nonsparking metal.

D.

located no closer than 3 ft. to the side of the tank.

Question 3

Exit signs shall have words on the sign in letters ___ inches in height.

Options:

A.

three

B.

four

C.

five

D.

six

Question 4

According to the fire code, when compliance is not immediate, inspection reports of code violations must always include a description of the violation and which of the following?

Options:

A.

The reinspection date

B.

The mandatory court date

C.

Recommended corrective action

D.

The potential fines for noncompliance

Question 5

Flammable medical gas supply cylinders located inside of a building must be stored in a separate room of not less than __ fire-resistive construction when exceeding 200 cu. ft.

Options:

A.

1/2-hour

B.

1-hour

C.

2-hour

D.

3-hour

Question 6

Conditions that may exist and warrant a modification include all of the following except where the:

Options:

A.

modification does not lessen health, life, and fire safety.

B.

modification requires the use of an alternative building material.

C.

modification is in compliance with the intent and purpose of the code.

D.

special individual reason makes the strict letter of the code impractical.

Question 7

Refrigeration units or systems having a refrigerant circuit containing Group A1 refrigerant shall be provided with approved emergency signs, charts, and labels in accordance with NFPA 704 when the quantity exceeds ___ lb.

Options:

A.

30

B.

100

C.

200

D.

220

Question 8

The minimum allowable distance to a public traffic route for storage of 1,750 lb. of Class 1.3 explosives is ___ ft.

Options:

A.

50

B.

75

C.

115

D.

150

Question 9

Where requirements for fire safety are not specifically provided for by the International Fire Code, which of the following shall have the responsibility to determine the applicable requirements?

Options:

A.

City manager.

B.

Legal counsel.

C.

Board of appeals.

D.

Fire code official.

Question 10

Given: A local college student inquires about the use of candles in their dorm room. Candles:

Options:

A.

may not be used.

B.

may be used in a sprinklered dormitory.

C.

must be kept a minimum 12 in. from combustibles.

D.

must be kept a minimum 36 in. from combustibles.

Question 11

The occupant load of an R-2 building's common patio area is to be calculated using the value:

Options:

A.

50 net per person.

B.

11 gross per person.

C.

15 gross per person.

D.

assigned by the code official.

Question 12

Churches, schools, apartment dwellings, and mercantile structures are commonly built using what type of construction?

Options:

A.

Type I

B.

Type II

C.

Type III

D.

Type IV

Question 13

At each grinding, buffing, or wire brushing operation on magnesium, other than the rough finishing of casting, dust must be collected by means of suitable hoods or enclosures connected to a:

Options:

A.

cloth screen arrestor.

B.

low-pressure cyclone.

C.

dry-type dynamic precipitator.

D.

liquid precipitation type of separator.

Question 14

The interior finish of walls and a ceiling in an atrium may not be less than __ Class

Options:

A.

A

B.

B

C.

C

D.

D

Question 15

What is the occupant load of a 50,000 gross square foot airport terminal concourse?

Options:

A.

200

B.

500

C.

1,000

D.

2,500

Question 16

An acceptance test for a fire alarm system in a new apartment building should be scheduled after:

Options:

A.

each zone is completed.

B.

the contractor verifies full compliance.

C.

the hydrostatic test of the underground main is completed.

D.

the system has been installed and operating for one year.

Question 17

Given: A nonsprinklered commercial Type II-B building has a fire flow requirement of 7,000 gpm. If a sprinkler system is installed throughout the building, the new required fire flow is at least ___ gpm. (Assume that the new required fire flow is sufficient to meet the requirements of the sprinkler system.)

Options:

A.

1,500

B.

1,750

C.

2,000

D.

2,250

Question 18

The maximum travel distance permitted in a one-story, Group F-2 building equipped with automatic sprinklers and automatic smoke and heat roof vents is __ ft.

Options:

A.

250

B.

300

C.

350

D.

400

Question 19

The fire code official has the right to enter a building to perform inspections in all of the following situations except:

Options:

A.

vacant buildings at any time.

B.

factory floors with permission to enter.

C.

public spaces of a mall during normal business hours.

D.

interior space of a warehouse with an administrative warrant.

Question 20

What fire-resistance rating is required for interior nonbearing walls and partitions in Type IV construction?

Options:

A.

0 hours

B.

1 hour

C.

1-1/2 hours

D.

2 hours

Question 21

Paint spray booths must have a clearance of ___ in. from unprotected combustible materials.

Options:

A.

12

B.

18

C.

24

D.

36

Question 22

A container in a clean-agent extinguishing system must be refilled or replaced when it shows a loss in original weight of more than five percent, or a loss in original pressure of more than ___ percent.

Options:

A.

3

B.

5

C.

10

D.

12

Question 23

Foamed plastics or materials containing foamed plastics used for stage scenery must be approved when tested in accordance with

Options:

A.

UL 1975

B.

NFPA 11A

C.

CPSC 16CFR

D.

ASTM D 1784

Question 24

Given: Scheduling inspections should be done to obtain a high level of efficiency. When scheduling inspections at multiple occupancies on the same day, the inspector should:

Options:

A.

only identify critical violations.

B.

set limits on the time spent at each occupancy.

C.

select occupancies in the same general area.

D.

select occupancies with historically low violations.

Question 25

In a motion picture theatre, an audible announcement shall be made to notify the occupants of the location of exits to be used in the event of a fire or other emergency not more than how many minutes prior to the start of each program?

Options:

A.

5

B.

10

C.

20

D.

30

Question 26

A building under construction which has two stairways shall have a minimum of how many fire extinguishers per floor?

Options:

A.

1

B.

2

C.

3

D.

4