A permit is required for storage of high-pile combustible stock in a building when the area of stock exceeds
Platforms used for access to aboveground tanks storing flammable or combustible liquids shall be:
Exit signs shall have words on the sign in letters ___ inches in height.
According to the fire code, when compliance is not immediate, inspection reports of code violations must always include a description of the violation and which of the following?
Flammable medical gas supply cylinders located inside of a building must be stored in a separate room of not less than __ fire-resistive construction when exceeding 200 cu. ft.
Conditions that may exist and warrant a modification include all of the following except where the:
Refrigeration units or systems having a refrigerant circuit containing Group A1 refrigerant shall be provided with approved emergency signs, charts, and labels in accordance with NFPA 704 when the quantity exceeds ___ lb.
The minimum allowable distance to a public traffic route for storage of 1,750 lb. of Class 1.3 explosives is ___ ft.
Where requirements for fire safety are not specifically provided for by the International Fire Code, which of the following shall have the responsibility to determine the applicable requirements?
Given: A local college student inquires about the use of candles in their dorm room. Candles:
The occupant load of an R-2 building's common patio area is to be calculated using the value:
Churches, schools, apartment dwellings, and mercantile structures are commonly built using what type of construction?
At each grinding, buffing, or wire brushing operation on magnesium, other than the rough finishing of casting, dust must be collected by means of suitable hoods or enclosures connected to a:
The interior finish of walls and a ceiling in an atrium may not be less than __ Class
What is the occupant load of a 50,000 gross square foot airport terminal concourse?
An acceptance test for a fire alarm system in a new apartment building should be scheduled after:
Given: A nonsprinklered commercial Type II-B building has a fire flow requirement of 7,000 gpm. If a sprinkler system is installed throughout the building, the new required fire flow is at least ___ gpm. (Assume that the new required fire flow is sufficient to meet the requirements of the sprinkler system.)
The maximum travel distance permitted in a one-story, Group F-2 building equipped with automatic sprinklers and automatic smoke and heat roof vents is __ ft.
The fire code official has the right to enter a building to perform inspections in all of the following situations except:
What fire-resistance rating is required for interior nonbearing walls and partitions in Type IV construction?
Paint spray booths must have a clearance of ___ in. from unprotected combustible materials.
A container in a clean-agent extinguishing system must be refilled or replaced when it shows a loss in original weight of more than five percent, or a loss in original pressure of more than ___ percent.
Foamed plastics or materials containing foamed plastics used for stage scenery must be approved when tested in accordance with
Given: Scheduling inspections should be done to obtain a high level of efficiency. When scheduling inspections at multiple occupancies on the same day, the inspector should:
In a motion picture theatre, an audible announcement shall be made to notify the occupants of the location of exits to be used in the event of a fire or other emergency not more than how many minutes prior to the start of each program?
A building under construction which has two stairways shall have a minimum of how many fire extinguishers per floor?