The output capacity of a single UPS is calculated on actual power when the actual load power is used for UPS configuration.
The civil air conditioners used by the FusionModule800 can start automatically after restoration of power failure.
The UPS5000-A has a built-in isolation transformer.
Which of the following statements are incorrect about the UPS 5000-A-400/500K? (Multiple Choice)
What is the maximum capacity of the UPS5000-E power module?
The number of batteries can be adjusted in the process of UPS configuration.
The Fusion Mod ule500 adopts free cooling.
The UPS5000-E (50 kVA power module) covers only a small floor area of (), which saves the space in the equipment room.
The efficiency of the UPS5000-E (25-75 kVA) power module is 96%.
Which of the following statements are correct about UPS5000-E bypass overload capacity? (Multiple Choice)
APM and NXR need to derate at 30°C, while the UPS5000-E does not need to derate below 40°C.
Which of the following statements are correct about the UPS5000-A-500K efficiency? (Multiple Choice)
Which of the following conditions shall be considered whencalculating the UPS rated inputcurrent?
(Multiple Choice)
Which of the following models has the widest input voltage range and is applicable to severe power grids?
For 80 kW IT loads, configuring an 80 kVA UPS can meet the basic requirements.
Which of the following are the optional components for the UPS2000-G series (6 kVA to 20 kVA)? () (Multiple Choice)
The UPS2000-G series (6 kVA to 20 kVA) supports up to () UPSs in parallel, providing excellent scalability.
The UPS backup duration is typically within 30 minutes. It is reasonable to calculate the battery capacity with the galvanostatic method.
If the voltage of a single battery in the battery string reaches (), the battery is in the danger state.
The UPS5000-E features wide voltage and frequency input range. It can be used in severe grid environments and extend the battery service life. What's the maximum input voltage range of the UPS5000-E?
The UPS5000-E (25-125 kVA) supports a maximum of () power modules.
The communication modes in a standard UPS5000-A include: (Multiple Choice)
The UPS5000-A can obviously reduce harmonic pollution to the power grid. The input current wave form distortion THDi is () at full linear loads.
Which of the following products is similar to the modular UPSs of the UPS5000-E series in product features?
Which of the following alarms can the UPS5000-A dry contact expansion card set? (Multiple Choice)
What differentiated features does the FusionModule800 have over competing products? () (Multiple Choice)
As the construction cost of the equipment room is high, reducing the floor area can efficiently save investment for clients. The floor area of a UPS5000-A-500K is ().
A wide input range effectively reduces the battery switch times, failure probability, and battery charge/discharge times, helping improve the battery life. The input voltage range of the UPS2000-G series (6 kVA to 20 kVA) is ( ).
The UPS5000-A has an industry-leading efficiency. It keeps a high efficiency within a wide load range, which greatly reduces the operating expense (OPEX) for clients. The highest efficiency can be().
The number of battery strings for the UPS5000-A can be adjusted. To avoid replacing the whole battery string due to one faulty battery and solve the battery maintenance difficulty of traditional UPSs.
Which of the following are the highlights of the UPS2000-G series (6 kVA to 20 kVA)? () (Multiple Choice)
The number of battery strings for the UPS5000-E (50 kVA power module) can be adjusted. To avoid replacing the whole battery string due to one faulty battery and solve the battery maintenance difficulty of traditional UPSs, the adjustable number of batteries in the UPS5000-E ranges from 30 to 44.
The model of the UPS2000-G-6KRTL is ( ).