If the application scenario of an N8500 clustered NAS system is Mac OS, the OS can access shared files on the N8500 through NFS.
In an OceanStor 9000 storage system, the management IP address is 100.16.100.3, the front-end service network segment is from 192.168.100.1 to 192.168.100.20, the dir00l directory is shared, and the share path is /dir00l. Which of the following statements about the share access are correct? (Select two)
If an application server cannot access the storage resources of an N8500 storage system, which of the following operations can be performed for troubleshooting? (Select three.)
An OceanStor 9000 storage system uses GE for the front-end network and 10GE for the back- end network. Which of the following statements is incorrect about the ports on the P node as shown in the figure?
Which of the following are considered when planning the deployment of an N8000 clustered NAS storage system? (Select three.)
Which of the following statements about the N8500 configuration prerequisites are correct? (Select three)
If the internal link is faulty in an N8500 clustered NAS storage system, which of the following items can be skipped during troubleshooting?
If the service disk in slot 35 on a C node of the OceanStor 9000 is faulty, you are supposed to find this disk at the front panel of the C node and then replace it.
Which of the following file system configurations are correct for the N8500 clustered NAS storage systems? (Select two.)
Which of the following statements about CIFS service parameter settings on an OceanStor 9000 storage system is incorrect?
When configuring file systems for the N8500 clustered NAS storage systems, you are advised to configure a file system size not larger than 32 TB and the size of small-file storage applications not larger than 16 TB to achieve satisfactory reliability and data recovery speed. (The small files here refer to the files with an average size of 1 MB.)
When planning RAID for an N8500 clustered NAS storage system, you are advised to configure RAID 10 for database services and random read/write services.
Which of the following network file sharing protocols are supported by a NAS storage system? (Select two.)
Which are the key parameters used to evaluate the performance of an N8500 clustered NAS storage system? (Select three.)
The HUAWEI OceanStor 9000 can be managed using web browsers. If an OceanStor 9000 storage system uses default settings, which of the following entered in the browser address box is correct?
The HUAWEI OceanStor Toolkit V100R001 is used for preventive maintenance. The preventive maintenance wizard does not include which of the following?
In the OceanStor 9000, a node pool is a collection of nodes that have the same characteristics such as physical type and access performance, and DST allows a user to divide physical nodes in the same file system into node pools.
If an OceanStor 9000 storage system consists of three P nodes and uses GE for the front-end network, how many IP addresses must be planned for the front-end service network segment?
The figure shows the rear view of a P node in an OceanStor 9000. When its front-end is a 10GE network and its back-end is an IB network, NICs 0 on all nodes in the basic cabinet must be connected to the GE switches in the same cabinet.
Which command is used to monitor the CPU usage in performance optimization of the N8500 clustered NAS storage systems?
When you are using the OceanStor Toolkit to deploy an OceanStor 9000 storage system, you must configure the front-end network mask, front-end network gateway, back-end network mask, back-end network gateway, management network mask, and management network gateway in the configuration file of the OceanStor Toolkit.
In the cluster communication architecture employed by an N8500 clustered NAS system, modules such as the resource agent, HAD, GAB, and Low Latency Transport (LLT) must collaborate to implement cluster communication. Which of the following statements about the work mechanisms of these modules are correct? (Select three)
The %util value of back-end disks frequently exceeds 90% after the iostat command is run. This indicates that the bandwidth utilization is high and performance bottlenecks exist.
When a NAS client attempts to connect to an OceanStor 9000 node, the user must enter the management IP address of the node.
When configuring an N8500 clustered NAS engine, a user must specify the start and end physical IP addresses and the start and end virtual IP addresses.
Which of the following must be considered before you optimize the performance of an N8500 clustered NAS storage system? (Select three)
When planning IP addresses for the back-end storage network of the OceanStor 9000 which uses IB networking, you must plan two back-end storage IP addresses and one temporary IP address for each node.
If an engine node of an N8500 storage system cannot be started, which of the following measures is incorrect?
Which of the following statements about the login information of the OceanStor 9000 after its software installation is complete are incorrect?
A customer's OceanStor 9000 big data storage system uses GE for the front-end network and 10GE for the back-end network. If the OceanStor 9000 is configured with four C nodes, only a basic cabinet is required.
The value of Huawei Oceanstor 9000infoTier is reflected in: (multiple choice)
In the OceanStor 9000 storage system, configure Info Allocator hard quotas for directory A and its subdirectories B to 1 GB and 2 GB, respectively.
The correct statement is: (multiple choice)
Use the Oceanstor systemReporter reporting tool to monitor the OceanStor 9000. The resource objects that can be monitored include: (multiple choice)
In the era of big data, you should also have big data thinking. Which of the following statements is incorrect?
Which of the following is incorrect about the N8500 configuration preparation?
Which of the following is incorrect about the description of the global cache of the OceanStor 9000?
In which of the following situations occurs, does the Huawei OceanStor 9000 system not start load balancing?
(Multiple choices) The value of Huawei OceanStor 9000 InfoTier is reflected in:
Which of the following is incorrect about the Oceanstor 9000Wushan file system description?
Huawei OceanStor 9000 storage system uses layered security maintenance. Which one is not the application layer security content?
The Huawei OceanStor 9000 integrates the hard disk resources of all nodes through DFS to provide a unified namespace.
Single-selection) Which of the following features of the OceanStor 9000 provides the features of the file system snapshot?
Huawei N8000 (V200R001) clustered between two nodes of the NAS, how many redundancy is between the heartbeat links?
The following statement about big data processing technology is: (multiple choice)
Which of the following descriptions of InfiniBand technology is wrong?
The initialization can be completed quickly by the Huawei OceanStor 9000 DeviceManager administrator. The initial configuration items include: (multiple selection)
(Optional) Which of the following modules or devices is not supported by the Huawei OceanStor 9000 FRU replacement tool?
Which of the following modules or devices is not supported by the Huawei OceanStor 9000 FRU replacement tool?
About CIFS sharing In Huawei's Oceanstor 9000C30 version, new features have been added. The following statement is correct: (multiple choice)
(Judgment) With Huawei OceanStor 9000 Device Manager, we can view the real-time OPS performance indicators of the system.
The following is true about the Huawei Oceanstor 9000 product software component description?
When performing maintenance on the Huawei OceanStor 9000 system, it is recommended that the system administrator perform routine checks on the account. The contents of the check include: (multiple choice)
The following statement about the Oceanstor 9000 Smart Load Balancing is correct: (multiple choice)
When the Oceanstor 9000 balancing policy switch is disabled, the node is expanded, the node is deleted or disabled, the hard disk is added, the hard disk is pre-disabled, and the disk is slowed down.
In the scenario, the system does not generate a balancing task. However, if the balancing policy switch is turned on after the node is deleted, the system automatically completes the data balancing.
Which of the following statements about the N8500 configuration process is correct?
Judgment) FusionStorage Block uses a unique data block segmentation technology and DHT Hash-based data routing algorithm.
To evenly distribute the volume's data across the larger resource pool fault domain, each volume can achieve greater IOPS and MBPS performance.
It also makes the load of each hardware resource relatively balanced.
Which of the following statements about the Oceanstor 9000 maintenance is incorrect?
The following statements about the N8500CIFS sharing are correct: (multiple choice)
The following is the command on the switch to detect the network. The first description: display Inter command can be used to view interface statistics and view switches.
Whether to record interface packet loss. The second description: display logbuf, if discarding, pay attention to whether there is a loop in the back-end networking.
What is the principle of the Erasure Code N+M redundancy technology implemented in the Oceanstor 9000?