Which technology does HPE OneView use to discover HPE ProLiant DL, ML, and Apollo servers automatically?
A systems administrator needs to add a VLAN to a network set to support a new application. They have added the network to the upstream switch and the Logical Interconnect Group in HPE OneView but traffic is not passing. What is the most likely cause of the problem?
A server administrator wants to prevent excessive unknown destination frames from affecting the network performance of Synergy compute modules. Which HPE OneView setting at the Logical Interconnect Group level can help?
What unique identifier does HPE OneView use to interact with each resource individually?
How would you export a list of only the active alerts within the HPE OneView?
Which HPE server platforms can be managed using HPE OneView? (Choose two.)
Which statement is true about consistency checks between the server profile template and its corresponding server profiles?
What is the correct procedure to configure this network?
How do you provide high availability on HPE oneview virtual appliance?
What is the effect of deleting a DL380 Gen10 server profile that defines local non-permanent volumes associated with that server profile?
Identify the HPE OneView object you would use to accomplish each task.
An administrator needs to customize the BIOS and local RAID configuration for a collection of HPE ProLiant servers. What should the administrator use to accomplish this task?
Which license is required to remotely access the DL server console and event logs?
Which component of HPE OneView provides information about temperature and CPU utilization for managed resources?
What are benefits of using templates with HPE OneView? (Select two.)
Exhibit:
A server administrator is creating a new SAN-attached volume as a part of a server profile definition. What will happen to the volume when the server administrator deletes the profile two weeks later?
Refer to the exhibit.
A server administrator wants to receive all the critical and warning alerts related to server using the profile “APPSRV 2”. What needs to be entered into the “Alert criteria” textbox to receive the right email alerts?
You are designing a new deployment consisting of HPE Proliant Gen10 rack servers and a Nimble storage array. Which data protection method is recommended to back up and be able to restore your appliance in case of a catastrophic failure?
Your customer needs to downgrade the firmware on a number of blades because they experienced issues with the current firmware. The customer modifies the server profile to the required firmware baseline and selects update, but the firmware downgrade is not successful.
What step needs to be taken to ensure the firmware downgrade is applied?
Which HPE OneView logical resource is used to define default server connectivity characteristics, such as the preferred and maximum bandwidth?
For multiple events to be identified as an SNMP trap storm, what criteria must the traps meet? (Choose three.)
Match the HPE OneView element to its definition.
You are designing a new deployment consisting of HPE Proliant Gen 10 rack server and nimple storage array. The hpe OneView virtual appliances will run on a esxi hypervisor.. which data protection method is recommended to backup and be able to restore your appliances in case of catrostopic failure.
A system administrator needs to update the firmware in all Virtual Connect Flex-10/10D modules. This needs to be done during a maintenance window, when the servers are powered off. Which firmware activation setting performs the update in the shortest possible time?
Match the HPE OneView interconnect module state to its definition. (Not all states will be used.)
a customer requires a report containing firmware revision of interconnect module across their blade system and synergy enclosures. Which management solution should you recommend?
A customer creates a server profile template with two new volumes. The first is an 8 GB LUN for the boot drive. The second is a 500 GB LUN for the ESXi cluster shared storage. After the server profiles are assigned to the servers they each have an 8 GB drive and a 500 GB drive but the 500 GB drive isn’t shared across the member nodes within the cluster.
What is the most likely problem with the Server Profile Template?
Your customer reports receiving an error after re-configuring some uplink sets. The error states that their Logical Interconnects are non-compliant with the Logical Interconnect Group. What must they do to clear this error?