Once a device is in an Open Replicator RecoverPoint session, what must be done in order to make configuration changes to that device?
Which statement is true about Logged Access mode?
An application team will be performing a major update to a RecoverPoint protected application. You have been asked by the application team for the best way to ensure a quick recovery at the remote cluster in case the update fails.
In RecoverPoint, what should be done to the associated Consistency Group?
Which RecoverPoint tool will recommend the preferred RPA you should assign to each Consistency Group?
In a VPLEX splitter environment, where is the splitter process running?
A company already using RecoverPoint/SE has just finished installing and configuring VPLEX. They are unable to use the VPLEX splitter.
What might cause this issue?
What is a named point-in-time copy of data marked by the system for recovery purposes within RecoverPoint?
A customer environment includes a two-cluster RecoverPoint/SE instance. They have a new data center 100 km away that they wish to protect with RecoverPoint.
What steps are required to connect a new cluster to their existing RecoverPoint instance?
A VMware user is currently protecting their virtual application servers with RecoverPoint. All data is stored on two VNX arrays. They will soon be adding Site Recovery Manager (SRM) to their VMware infrastructure.
What will be needed to integrate RecoverPoint functionality into their SRM deployment?
When is the Open Replicator RecoverPoint session created for each production volume in the Consistency Group (CG)?
What is a characteristic of a full sweep?
You are concerned about the performance of the RecoverPoint replication. Some of the Consistency Groups continue to go into High Load. Initial troubleshooting points to a data compression issue.
Which command will determine if compression is set too high?
Refer to the exhibit.
A customer is implementing a RecoverPoint solution with a two-node cluster. What is represented by the 'A' in the exhibit?
When modifying a cluster's settings, what value can be changed from the Environment Settings screen in Deployment Manager?
Which connectivity protocols are used to interconnect RecoverPoint clusters?
Your business is planning to deploy RecoverPoint for your DR solution. What is an important consideration when using Consistency Groups in RecoverPoint 4.1?
A company with a DR site connected with a 2 Gbps FC link has three vRPAs at each site. They are experiencing High Load events, although the FC link is not fully utilized.
What would be the best solution to get the FC link utilization up as high as possible while mitigating those events?
Which RecoverPoint volume type stores information about the cluster and must be accessible by all RPAs?
Which FA ports must the production LUN be mapped to in order to perform write splitting using the VMAX splitter?
A company has a RecoverPoint cluster in a remote replication environment that has several Consistency Groups. The Consistency Groups are constantly going into High Load. After reviewing the Unisphere for RecoverPoint event log, you see the following event:
Journal is unable to handle the incoming data rate
What should you review to identify the problem?
A company is currently using RecoverPoint/SE in their environment. They have purchased a VMAX which will be deployed to replace the VNX splitter at one site only.
What must be done before they can use the VMAX with RecoverPoint (RP)?
What is the maximum supported storage capacity, per license, for an EMC RecoverPoint/EX environment?
What would cause a volume sweep to occur?
Refer to the exhibit.
A RecoverPoint cluster with two RPAs and VPLEX splitter has been deployed. When you run the rp validate-configuration VPLEX CLI command, the error shown in the exhibit is displayed.
What is the most likely cause of this error?
You ran Collect System Information from an RPA. However, you forgot where you specified to save the logs on the FTP server.
What is the recommended way to retrieve the logs?
What is a quick way to determine if the required TCP ports for RecoverPoint are blocked?
You are adding an RPA to a cluster using Deployment Manager. What requirement must be satisfied before proceeding?
Which Open Replicator mode is used by the RecoverPoint VMAX write splitter?
When designing an EMC RecoverPoint environment, what must be taken into account when a site consists of multiple VMAX splitters or multiple RecoverPoint clusters?
What does the MetroPoint feature provide?