Winter Special Flat 65% Limited Time Discount offer - Ends in 0d 00h 00m 00s - Coupon code: suredis

EMC D-PST-MN-A-24 Dell PowerStore Maintenance Achievement Exam Practice Test

Demo: 18 questions
Total 61 questions

Dell PowerStore Maintenance Achievement Questions and Answers

Question 1

While on-site installing a Dell EMC PowerStore system, the node A and B embedded module fault LEDs are alternating blue and amber (blue for 3 seconds). What does this

indicate?

Options:

A.

Nodes are in service mode

B.

Nodes are in degraded mode

C.

The system is not initialized

D.

The system is booting

Question 2

What does the output of the command "svc_diag list -- basic" show?

Options:

A.

Failover status

B.

Service tag

C.

Boot mode

D.

License status

Question 3

Correctly order the steps of the embedded module replacement procedure.

Options:

Question 4

What describes Dell EMC PowerStore X front-end cabling?

Options:

A.

Uses internal VMware virtual switching and does not require a management network

B.

Management and discovery use the same cables and connections as storage

C.

Storage and management use the same LACP bonded cable connection

D.

Uses VLTi data switch interconnectivity to support vMotion networks

Question 5

When a Dell EMC PowerStore node powers up in service mode, what are the commands and sequence used from the appliance SSH client to restore the node back to normal?

Options:

A.

svc_node restart

svc_rescue_state start

B.

svc_node shutdown

svc_rescue_state clear

C.

svc_rescue_state clear

svc_node reboot

D.

svc_rescue_state normal

svc_node start

Question 6

From where can a data collection be initialized within Dell EMC PowerStore Manager?

Options:

A.

Appliance, node, and storage resource

B.

Cluster, appliance, and event log

C.

Cluster, appliance, and alerts

D.

Node, storage resource, and alerts

Question 7

How can the PUHC health check results be viewed?

Options:

A.

From syslog server

B.

In Details of Appliances and Nodes

C.

From management DB

D.

By accessing the Swagger UI

Question 8

What is the protocol used for the storage network?

Options:

A.

NFS

B.

FC

C.

iSCSI

D.

SMB

Question 9

What is the reason for the best practice of leaving 2 Us of space at the bottom of the rack when racking Dell EMC PowerStore systems?

Options:

A.

Provide cooling air intake

B.

Leave room for serviceability

C.

Leave clearance for wheel roll

D.

Provide better rack stability

Question 10

Which component is an FRU?

Options:

A.

DIMMs

B.

Embedded IO Module

C.

Nodes

D.

Battery Backup Unit

Question 11

Which account credentials are needed to run diagnostic commands?

Options:

A.

console

B.

service

C.

root

D.

admin

Question 12

A Storage Administrator needs to add drives to a base enclosure of a Dell EMC PowerStore 3000X system. The system currently contains 10 750-GB NVMe SCM drives.Which

drive configuration maximizes the base enclosure capacity?

Options:

A.

13 750-GB NVMe SCM drives in slots 10-22

B.

11 750-GB NVMe SCM drives in slots 10-20

C.

13 15360-GB NVMe SSD drives in slots 10-22

D.

11 15360-GB NVMe SSD drives in slots 10-20

Question 13

What is an alternative way to collect logs instead of using the Dell EMC PowerStore manager GUI?

Options:

A.

Data Collect using Service Container

B.

USB stick inserted into the system

C.

Data Collect using vCenter

D.

Discovery Utility

Question 14

Through which network do external hosts connect to the cluster for data access?

Options:

A.

Storage

B.

Management

C.

Service

D.

Internal

Question 15

What is the alert severity if the license expiration date is within a week?

Options:

A.

Minor

B.

Major

C.

Information

D.

Warning

Question 16

How many nodes are in the base enclosure?

Options:

A.

1 node with duel connectivity

B.

1 node with high availability enabled

C.

2 nodes configured as Active-Active

Question 17

In which step of the ICW can the configuration details be exported?

Options:

A.

Support Assist

B.

Cluster Configuration

C.

Cluster Details

Question 18

Refer to the exhibit.

What Dell EMC PowerStore ToR front-end cabling is shown?

Options:

A.

VLT interconnectivity

B.

OOB Management

C.

Management and discovery

D.

Core switch uplink

Demo: 18 questions
Total 61 questions