A PDD has been created which includes a requirement to log in to an application called CDS. The CDS application only allows a user account to be logged into the application on one machine at a time. The client wishes to hold the credentials for logging into CDS in the Blue Prism Credential store.
It has been calculated that the automated solution will require 3 resource PC's to enable the case volume to be worked within SLA’s.
Which is the most appropriate design decision to accommodate the above requirements?
The following screen displays order details in a client’s order system application. An order is entered into the Order number field and the details for that order are displayed. There is a requirement to read the Product code value from the resulting display. The Product code will vary between orders.
The Product Code label has been successfully spied and the following attributes have been returned:
The Product Code value field has been spied and the following attribute set has been selected:
In order to ensure a consistent match for the Screen Text – Product Code element, which of the following statements must be considered:
1. The Dynamic value of the Y attribute for the Screen Text – Product Code element must be derived from the Y attribute of the Label –Product Code element
2. The Y attribute of the Label –Product Code element cannot be derived as it is not checked
3. The Y attribute for the Screen Text – Product Code element must be set to a Match Type of ‘Equal’
4. The Window Text attribute for the Screen Text – Product Code element must be set to a Match Type of ‘Wildcard’
5. The Window Text attribute for the Screen Text – Product Code element must be un-checked
Which of the following statements about setting and using Work Queue priority are correct?
The Blue Prism Work Queue business object can be used to change the priority of an item after it has been added to the queue.
Items are worked in order of lowest priority number first.
The default priority setting is 1.
Setting the priority for a Work Queue item is done when the item is first added to the queue using the Add To Queue action.
When using Surface Automation which of the following is a valid Action within a Read Stage to read a numeric value from a field which has been identified as a Region?
Study the process flow below:
The initial values for the Loop Count and Max Loop data items are 0 and 5 respectively.
How many times will the Process ‘Open Account Part 1’ be read into memory during the execution of the Process?
While automating a process involving a browser based application a popup window from the browser application appears that you need to work with. When you try to spy the popup window and its elements, Blue Prism throws the following error: “There was an error during the spying operation.” Which of the following would be the most appropriate workaround?
While trying to read a table in a browser based application into a collection an error message appears and the table cannot be read directly into the collection. This happens when using either AA or HTML mode. Which of the following would be the most appropriate workaround?